Jawaban singkat
Under the ADA a ramp may be no steeper than 1:12, 1 in of rise for every 12 in of length, and one run may climb at most 30 in before a 60 in landing. A 24 in rise therefore needs 24 ft of ramp plus landings at the top and bottom.
Hitung sekarang
Ramp calculator
Length, landings and width of a wheelchair ramp for your height.
Ramp calculator →Slope, rise and run
Slope is the rise divided by the horizontal length. 1:12 means 1 unit up for every 12 along, which is 8.33 %. A run is one sloped part between level landings. Landings give a place to rest, turn and open doors.
The rules side by side
The ADA standards apply to public and commercial facilities in the United States, Approved Document M Volume 2 to buildings other than dwellings in England and Wales, and DIN 18040 to accessible buildings and dwellings in Germany.
| ADA (US) | Approved Document M (England, Wales) | DIN 18040 (Germany) | |
|---|---|---|---|
| Steepest slope | 1:12 (8.33 %) | 1:12 for a 2 m run, 1:15 for 5 m, 1:20 for 10 m | 6 % |
| Longest run | Rise of 30 in (762 mm) | 10 m going, 500 mm rise | 6 m |
| Landings | 60 in (1524 mm) at top, bottom and between runs | 1.2 m at the ends, 1.5 m between runs | 1.5 m between runs, 1.5 × 1.5 m at the ends |
| Clear width | 36 in (914 mm) | 1.5 m | 1.2 m |
| Cross slope | 1:48 max. | — | None |
| Handrails | Both sides when the rise is more than 6 in | Both sides | — |
Approved Document M also says that a ramp rising more than 300 mm in total should have steps as well, and above 2 m another way up, such as a lift. Its slopes between the listed run lengths are interpolated: 1:14 for a 4 m run, 1:19 for 9 m.
Worked example: a 24 in porch under the ADA
- Length of slope: 24 in × 12 = 288 in = 24 ft.
- Rise of one run: 24 in is below 30 in, so one run is enough.
- Landings: 60 in at the bottom and 60 in at the top.
- Total length: 24 ft + 5 ft + 5 ft = 34 ft.
- Handrails on both sides, because the rise is more than 6 in. Clear width at least 36 in.
A 36 in rise would need two runs of 18 in each, 18 ft long, with a 60 in landing between them.
Worked example: a 50 cm rise under DIN 18040
- Length of slope at 6 %: 0.50 / 0.06 = 8.33 m.
- Runs: at most 6 m each, so two runs of 4.17 m with a 1.5 m landing between them.
- Level areas of 1.5 × 1.5 m at the start and the end.
- Total length: 8.33 + 1.5 + 1.5 + 1.5 = 12.83 m.
This is why ramps at the entrance of a house often turn back on themselves: 13 m of straight ramp rarely fits in front of a door.
Tanya jawab
How long does a ramp need to be?
At 1:12, 12 times the rise: 1 ft of ramp for every 1 in of rise. A 24 in rise needs 24 ft, plus landings.
What is 1:12 as a percentage?
8.33 %. It is about 4.8°.
How often does a ramp need a landing?
Under the ADA after every 30 in of rise. Under DIN 18040 after every 6 m of length. Under Approved Document M after every 10 m of going or 500 mm of rise, and less where the slope is steeper.
How wide should a ramp be?
At least 36 in (914 mm) clear under the ADA, 1.5 m under Approved Document M, and 1.2 m under DIN 18040.
Does a ramp at a private house have to follow the ADA?
The ADA standards are written for public and commercial facilities. For a private home check your local rules; the ADA numbers are a well-documented target if a wheelchair user will use the ramp.
Hitung sekarang
Ramp calculator
Length, landings and width of a wheelchair ramp for your height.
Ramp calculator →Sumber
- [1]Guide to the ADA Accessibility Standards, Chapter 4: Ramps and Curb Ramps. U.S. Access Board. ADA 2010 Standards, 405: running slope 1:12 maximum, cross slope 1:48 maximum, rise of a run 30 in maximum, clear width 36 in minimum, landings 60 in long at top, bottom and between runs (60 × 60 in where the ramp turns), handrails on both sides when the rise is greater than 6 in, handrail height 34 to 38 in.. Diperiksa 11 November 2026
- [2]Approved Document M, Access to and use of buildings, Volume 2 (Wales, 2025), para 1.26 and Table 1. Welsh Government. Maximum gradient by going of a flight: 2 m 1:12 (166 mm rise), 5 m 1:15 (333 mm), 10 m 1:20 (500 mm), interpolated between (1:14 at 4 m, 1:19 at 9 m); no flight longer than 10 m or higher than 500 mm; width at least 1.5 m; landings 1.2 m at foot and head, intermediate landings 1.5 m; handrail on both sides; steps in addition above 300 mm total rise; another way up such as a lift above 2 m. Same table as Approved Document M Volume 2 for England.. Diperiksa 11 November 2026
- [3]Hinweise zum barrierefreien Bauen nach DIN 18040 (Merkblatt 202, 05/2017). Architektenkammer Niedersachsen. DIN 18040-1 and -2: ramp runs at most 6 % with no cross slope; an intermediate landing 150 cm long after at most 600 cm; level areas of 150 × 150 cm at the start and end; usable width at least 120 cm.. Diperiksa 11 November 2026