Skip to content
Yardox

Stair rise and run: what the codes allow

Every stair is a compromise between floor space and comfort. Building codes set the outer limits; inside them you choose how steep the stair feels.

Updated November 6, 2026

Short answer

Under the IRC a house stair may have risers up to 7¾ in and treads of at least 10 in, a clear width of 36 in and 6 ft 8 in of headroom. Under DIN 18065 a house stair has risers of 14–20 cm, a going of 23–37 cm, a width of at least 80 cm and 2.00 m of headroom.

Calculate it

Stair calculator

Riser and tread sizes, stringer length, code check.

Stair calculator →

The limits side by side

These are the figures for stairs inside one- and two-family homes. Commercial and public buildings have stricter rules.

House stairs: IRC section R311.7 and DIN 18065
IRC (USA)DIN 18065 (Germany)
Riser heightmax. 7¾ in (197 mm)14–20 cm
Tread depth (going)min. 10 in (254 mm)23–37 cm
Clear widthmin. 36 in (914 mm)min. 80 cm
Headroommin. 6 ft 8 in (2.03 m)min. 2.00 m
Largest vs smallest riser or tread in a flightmax. ⅜ in (9.5 mm) difference—
Highest flight without a landing12 ft 7 in (3.84 m)—

Many US states and cities adopt the IRC with their own amendments, and some rules change between editions. Treat the table as the model code and confirm with your local building department before you cut stringers.

How risers and treads are measured

The IRC measures the riser vertically between the leading edges of two neighbouring treads, and the tread horizontally between the front edges of two neighbouring treads. The nosing overhang is not part of the tread depth.

A nosing of ¾ to 1¼ in is required on treads under 11 in deep. With treads of 11 in or more it is optional.

Measure the total rise from finished floor to finished floor. If the lower floor gets 20 mm of tile later and you measure from bare concrete, the first riser ends up 20 mm shorter than the others, and that difference alone is already more than the ⅜ in the IRC allows.

Nosing lineHeadroom ≥ 6 ft 8 inTread ≥ 10 inRiser ≤ 7¾ inNosing ¾–1¼ inTotal rise
How the IRC measures a stair: the riser between the tops of two treads, the tread depth between two nosing edges, headroom up from the line through the nosings.

The step rule: 2 × rise + going

Codes give limits, not comfort. For comfort, German practice uses the step rule: twice the riser plus the going should be 59–65 cm, about 63 cm on average, which is roughly the length of an adult's pace. In inches that is about 23¼–25⅝ in, 24¾ in on average.

A steeper stair (taller risers, shorter treads) saves floor space. A shallower one is easier to walk, especially carrying things or for older people.

Worked example: 8 ft 9 in floor to floor (IRC)

Total rise: 105 in. Divide by the maximum riser: 105 / 7.75 = 13.5, so at least 14 risers.

14 risers of 105 / 14 = 7½ in each. A straight flight that lands on the upper floor has one tread fewer than risers: 13 treads.

With 10 in treads the run is 13 × 10 = 130 in, or 10 ft 10 in. Check the step rule: 2 × 7.5 + 10 = 25 in, inside the comfortable range.

Worked example: 2.75 m floor to floor (DIN)

Here the choice of riser count changes the stair a lot.

  • 14 risers of 19.6 cm. The step rule with 63 cm gives a going of 23.7 cm. Run: 13 × 23.7 = 3.08 m. Legal, compact, and steep.
  • 16 risers of 17.2 cm. Going: 63 − 2 × 17.2 = 28.6 cm. Run: 15 × 28.6 = 4.29 m. More than a metre longer, and much easier to climb.

Both layouts meet DIN 18065 for a house. Which one fits depends on the floor plan, and that trade-off is exactly what a stair calculator lets you try in a few seconds.

Questions

What is the maximum stair riser height in the US?

For homes built under the IRC, 7¾ in, measured between the leading edges of adjacent treads. Within one flight the tallest riser may not exceed the shortest by more than ⅜ in.

What is the minimum stair tread depth?

10 in under the IRC, measured without the nosing. DIN 18065 asks for at least 23 cm in a house.

How much headroom does a staircase need?

6 ft 8 in under the IRC, in all parts of the stairway. DIN 18065 asks for 2.00 m, measured vertically from the line of the tread nosings.

How many steps do I need for 9 ft floor to floor?

108 in divided by the 7¾ in maximum is 13.9, so 14 risers of about 7.71 in, and 13 treads in a straight flight. Measure from finished floor to finished floor, not to the ceiling.

Calculate it

Stair calculator

Riser and tread sizes, stringer length, code check.

Stair calculator →

Sources

  1. [1]IRC Code Handout #437: Stairway treads and risers (02/2022). City of Boise, Planning & Development Services. IRC R311.7.5: riser not more than 7¾ in, tread not less than 10 in, largest riser or tread in a flight within ⅜ in of the smallest; nosing ¾ to 1¼ in, not required where treads are 11 in or deeper. How risers and treads are measured.. Checked November 5, 2026
  2. [2]Minnesota Rules 1309.0311: amendments to IRC section R311 (2020). Minnesota Office of the Revisor of Statutes. Code text: stairways not less than 36 in clear width; headroom in all parts of the stairway not less than 6 ft 8 in.. Checked November 5, 2026
  3. [3]WAC 51-51-0311: IRC section R311 as adopted in Washington (2023). Washington State Legislature. R311.7.3: a flight of stairs shall not have a vertical rise larger than 12 ft 7 in between floor levels or landings.. Checked November 5, 2026
  4. [4]Stufen: Definition, Begriffe und Regeln. BauNetz Wissen. DIN 18065 for buildings with up to two dwellings: rise 14–20 cm, going 23–37 cm, clear width at least 80 cm (other buildings 14–19 cm, 29–37 cm, 100 cm).. Checked November 5, 2026
  5. [5]Treppendurchgangshöhe. BauNetz Wissen. DIN 18065: clear headroom at least 200 cm, measured vertically from the line of the nosings.. Checked November 5, 2026
  6. [6]Treppe berechnen. TÜV SÜD. Step rule 2 × rise + going = 59–65 cm for adults, 63 cm on average.. Checked November 5, 2026