Air conditioner size calculator (BTU)
Find what size air conditioner, mini-split or heat pump your rooms need, in BTU, kW and tons.
Rooms to cool
Enter the floor area of each room. You get the cooling capacity to look for on the air conditioner or heat pump, in Btu/h, kW and tons.
Rooms
One row per room with its own indoor unit or window unit. For a multi-split system add all rooms it serves.
Ceiling height and heating with a heat pump
The chart is worked out for 8 ft (2.44 m) ceilings.
For a heat pump that also heats: the heat load from the heat loss calculator. Leave empty for cooling only.
Add this calculator to your website
Free for any website: paste this code where the calculator should appear. It keeps itself up to date, fits its height to the content and links back to the full page with the explanations.
Como usar
- 01Enter the floor area of the room you want to cool.
- 02Choose how sunny it is, enter how many people regularly use it, and tick the box if it is a kitchen.
- 03For a multi-split system with one outdoor unit, add a row for every room it serves.
- 04Read the cooling capacity in kW, BTU per hour and tons. Choose a unit rated at least that much, not much more.
- 05For a heat pump that also heats, enter the heat load from the heat loss calculator under "Ceiling height and heating".
Como é calculado
The capacity comes from the room air conditioner sizing chart of ENERGY STAR, the US government efficiency programme. It gives the cooling capacity for the floor area of a room with an 8 ft ceiling, from 5,000 Btu/h for 100 to 150 ft² up to 34,000 Btu/h for 2,000 to 2,500 ft².
- Room
- Q = chart(A) ± 10 % sun + 600 × (people − 2) + 4,000 kitchen
- Several rooms
- Q total = Q1 + Q2 + …
- Kilowatts
- kW = Btu/h / 3,412
- Tons
- t = Btu/h / 12,000
ENERGY STAR adjusts the chart value: 10 % less for a heavily shaded room, 10 % more for a very sunny one, 600 Btu/h for every person above two who regularly uses the room, and 4,000 Btu/h in a kitchen.
One ton of cooling is 12,000 Btu/h; one kilowatt is 3,412 Btu/h. Mini-splits sold in Europe are rated in kW, in North America in Btu/h.
The chart is a rule for single rooms. Whole houses and ducted systems are sized by a room-by-room load calculation, ACCA Manual J in North America or EN 12831 for heating in Europe. A unit that is too large cools the air quickly, switches off and leaves the room damp, so do not round up much.
A heat pump has to cover the heating load too. Enter the heat load from the heat loss calculator and the calculator shows the larger of the two.
Exemplo de cálculo
A 20 m² living room and a 14 m² sunny bedroom on one multi-split
- 20 m² = 215 ft², in the 150 to 250 ft² band: 6,000 Btu/h.
- 14 m² = 151 ft², also 6,000 Btu/h; very sunny, plus 10 %: 6,600 Btu/h.
- Together 12,600 Btu/h, which is 3.69 kW or 1.05 tons.
- A 3.5 kW outdoor unit is just short; choose the next size up, with an indoor unit of about 2 kW in each room.
Como acertar na compra
Do not oversize
An oversized unit switches on and off often, wastes energy and removes little moisture, so the room feels clammy. Pick the size closest to the result.
Shade the windows first
Outside blinds or awnings on sunny windows cut the load more than any extra capacity adds. The chart counts them as shade.
Check heating output in the cold
For a heat pump, look at the heating output at your design outdoor temperature in the data sheet, not only the rated value at +7 °C.
Mind the ceiling
The chart assumes 8 ft (2.44 m) ceilings. Lofts and rooms under a roof need more; ask the installer for a load calculation.
Erros comuns
- Buying the largest unit "to be safe".
- Ignoring the kitchen: cooking adds 4,000 Btu/h.
- Using one room unit to cool several closed rooms.
- Sizing a heat pump on cooling alone in a cold climate.
Perguntas
How many BTU do I need per square foot?
It is not a fixed figure per square foot: the ENERGY STAR chart gives 5,000 Btu/h for 100 to 150 ft², 12,000 Btu/h for 450 to 550 ft² and 24,000 Btu/h for 1,400 to 1,500 ft², then adds for sun, people and a kitchen.
What size mini-split do I need for 500 square feet?
12,000 Btu/h (1 ton, 3.5 kW) for a normal room; 13,200 Btu/h if it is very sunny.
How many kW of cooling for a 20 m² room?
20 m² is 215 ft², which the chart puts at 6,000 Btu/h, or 1.76 kW, before sun, people and kitchen.
What is a ton of air conditioning?
A cooling capacity of 12,000 Btu/h, about 3.5 kW.
Calculadoras relacionadas
Fontes
- [1]Room Air Conditioners: find the correct cooling capacity. ENERGY STAR (U.S. EPA and DOE). Capacity by area cooled (based on an 8-foot ceiling), 100 to 2,500 ft²: 5,000 to 34,000 Btu/h. Adjustments: heavily shaded −10 %, very sunny +10 %, +600 Btu/h for each person above two who regularly occupies the room, +4,000 Btu/h in a kitchen.. Conferido em 18 de novembro de 2026
- [2]Building America Solution Center: Air Conditioning. Pacific Northwest National Laboratory (U.S. DOE). One ton equals 12,000 Btu/h of cooling capacity. Cooling systems should not be oversized; the whole-house load is calculated with ACCA Manual J.. Conferido em 18 de novembro de 2026
Última conferência das fórmulas e fontes em 18 de novembro de 2026. Como calculamos