Ir para o conteúdo
Yardox
Esta versão está em revisão por um falante nativo. Alguns termos podem mudar.

Water heater size calculator

Find what size water heater your household needs: the first hour rating of a tank, or the flow and power of a tankless heater.

Your household

Type of water heater

A tank is chosen by its first hour rating: how much hot water it delivers in one busy hour. That must cover your peak hour, counted after the US Department of Energy worksheet.

A water heater with cold water in and hot water out to a shower and a tap220 L10 °C49 °C

Your busiest hour

How often each happens in the hour when most hot water is used, usually the morning.

76 L each

8 L each

11 L each

26 L each

95 L each

57 L each

First hour rating at least220 L
Add this calculator to your website

Free for any website: paste this code where the calculator should appear. It keeps itself up to date, fits its height to the content and links back to the full page with the explanations.

Como usar

  1. 01Choose a tank (or heat pump) water heater, or a tankless one.
  2. 02For a tank: enter how many showers, shaves, washer and dishwasher runs happen in your busiest hour of the day.
  3. 03Read the first hour rating to look for on the label. It must be at least your peak hour demand.
  4. 04For a tankless heater: enter how many showers and taps run at the same time, their flow, and the cold and hot water temperatures.
  5. 05Read the flow and heating power the tankless heater must give.

Como é calculado

Both methods come from the US Department of Energy guide to sizing a new water heater.

Peak hour demand
V = Σ uses × gallons per use
Tank
first hour rating ≥ V
Tankless flow
Q = Σ flows of outlets used at once
Tankless power
P (Btu/h) = 500.6 × Q (gpm) × ΔT (°F)

Gallons per use from the DOE worksheet: shower 20, shave 2, washing dishes or food by hand 3, dishwasher 7, top-loading washer 25, front-loading washer 15. One US gallon is 3.785 litres.

A tank heater is labelled with its first hour rating: the hot water it delivers in an hour starting full. It is not the tank size; a heater with a quick burner gives more than its tank holds.

For a tankless heater the DOE adds the flow rates of the outlets used at once, such as a 0.75 gpm tap and a 2.5 gpm shower, and takes the incoming water as 50 °F (10 °C) unless you know better. The power follows from the flow: a gallon of water at 50 °F weighs 8.34 lb (USGS), and 1 Btu warms 1 lb by 1 °F, so 1 gpm needs 500.6 Btu/h per °F of rise.

The DOE notes that gas tankless units reach a 70 °F (39 °C) rise at about 5 gpm and electric ones at about 2 gpm. The calculator warns when you need more.

Exemplo de cálculo

A family of four on a weekday morning

  1. Busiest hour: 3 showers, 1 shave, 1 hand dishwashing.
  2. 3 × 20 + 2 + 3 = 65 gallons (246 L).
  3. Choose a tank with a first hour rating of at least 65 gallons.
  4. Tankless: a shower (2.5 gpm) and a tap (0.75 gpm) together are 3.25 gpm (12.3 L/min).
  5. At a 70 °F rise: 500.6 × 3.25 × 70 = 113,900 Btu/h, about 33.4 kW.

Como acertar na compra

Look at the first hour rating, not the tank size

Two tanks of the same size can give very different amounts of hot water in an hour. The rating is on the yellow EnergyGuide label in the US and in the data sheet elsewhere.

Electric tankless needs a big supply

Over 30 kW for a shower and a tap is more than many homes can take. Check the electrical supply before choosing an electric tankless heater.

Spread the morning rush

Running the washer or dishwasher outside the busiest hour lowers the rating you need.

Check the shower flow

Time how long a shower takes to fill a bucket. Low-flow heads cut both the hot water and the heater size.

Erros comuns

  • Choosing a tank by the number of people instead of the busiest hour.
  • Adding every tap in the house for a tankless heater instead of those used at once.
  • Forgetting that winter supply water is colder, so a tankless heater gives less flow.
  • Buying an electric tankless heater without checking the supply.

Perguntas

What size water heater do I need for a family of 4?

Count the busiest hour: three showers, a shave and dishes by hand come to 65 gallons (246 L), so look for a first hour rating of at least 65 gallons.

How many gallons does a shower use?

The DOE worksheet counts 20 gallons (76 L) of hot water per shower.

What size tankless water heater do I need?

Add the flow of the outlets used at once, for example 2.5 gpm for a shower and 0.75 gpm for a tap, then find the power for your temperature rise: 3.25 gpm at 70 °F needs about 114,000 Btu/h.

Is the first hour rating the tank size?

No. It is how much hot water the heater delivers in one hour starting with a full tank, including what it heats in that hour.

Fontes

  1. [1]Sizing a New Water Heater. U.S. Department of Energy, Energy Saver. Storage and heat pump water heaters: choose a first hour rating at least equal to the peak hour demand. Gallons per use: shower 20, shaving 2, hand dishwashing or food prep 3, automatic dishwasher 7, top-loading clothes washer 25, front-loading (H-axis) 15. Tankless: add the flow rates of devices used at once (example 0.75 gpm faucet, 2.5 gpm shower); incoming water 50 °F (10 °C) unless known; 120 °F (49 °C) for most uses; gas units reach a 70 °F rise at 5 gpm, electric at 2 gpm.. Conferido em 18 de novembro de 2026
  2. [2]Water Density (Water Science School). U.S. Geological Survey. Water at 50 °F (10 °C) weighs 62.408 lb/ft³ (0.99975 g/cm³); with 1 Btu per lb per °F this gives the heat to warm a flow of water.. Conferido em 18 de novembro de 2026

Última conferência das fórmulas e fontes em 18 de novembro de 2026. Como calculamos